12 Technical Rules of Thumb for Installing Zoning

Z-300-HPS
1. In most cases, it will not be necessary to modify the duct sizing when installing a zoning system.
2. It is good practice to size the smallest zone to handle approximately 25% of the system CFM.
3. Never undersize ductwork.
4. Upsizing registers in the smallest zone to the next larger size should be considered.
5. You can double the rated CFM of a register before it starts to get noisy.
6. Two-stage equipment is always a better choice.
7. It is always better to slightly undersize the HVAC equipment than to oversize it.
8. Never locate a thermostat in a hallway.
9. Dampers should be installed at least 2 feet away from the plenum, when possible.
10. Always use a separate 24 volt transformer to power the zone panel. Do not use the equipment transformer.
11. Always tag wires, especially from dampers and thermostats.
12. Some basements may require setting the zone thermostat in the auto mode during the cooling season due to cold walls, uninsulated ductwork or leaking ductwork.